Cadac R-Type Manuel d'utilisateur Page 49

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 139
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 48
Central Control Module 8281 6-9
Revision R2005-2 R-Type
91719 'HEXJ#0HQX
The debug menu provides a number of facilities to assist in fault finding and preven-
tive maintenance.
Press SYS and use the down arrow key to go to Debug. Press Enter to show the
debug menu.
9171914 6KRZ#WHPS
Using the arrow key, go to Show Temp. Press Enter and the display will show the
temperature in the console. Press ESC to leave.
9171915 6KRZ#WLPH
Press the down arrow key to go to Show Time. Press Enter to have the display show
the Time. The Edit button will at this point be flashing to indicate the time shown may
be edited. To edit the Time, press EDIT and using the arrow key, go to Set Time.
When completed press Enter.
Press ESC to go to the previous menu level.
9171916 6KRZ#GDWH
Using the down arrow key, go to Show Date, then press Enter to show the Date. To
Edit the date, press EDIT.
Pressing ESC takes you back to the menu.
9171917 6KRZ#368 ·V
Press SYS and use the arrow key to go to the Debug menu, press Enter and then the
up or down arrows again to go to Show PSU’s. Press Enter and the display will show:
+18V
actual = xx.x
Using the arrow keys allow you to move around and check the carious voltages sup-
plied by the PSU’s. Pressing ESC takes you back to the menu.
9171918 6KRZ#YHUVLRQ
Press SYS and use the down arrow key to go to the Debug menu, press Enter and
then the up or down arrows again to go to Show version. Press Enter and the display
will show the software version number and date when it was compiled.
Press ESC to go to the menu.
9171919 6KRZ#HUURUV
The R-Type is equipped with an error log that stores brief information about faults
that occur and the date/time when they occurred. This feature is useful to CADAC
engineers in diagnosing a fault after the event.
Press SYS, then using the down arrow key, go to the Debug menu, press Enter and
then the up or down arrows again to go to Show errors and press Enter. The display
will show the type of error and the Date/Time when it occurred. Navigate the list of
errors using the up/down arrow keys.
The CLR button flashes, indicating that the error log can be cleared. Press Enter and
the display shows Error log cleared. Press ESC to go back to the menu.